What is it about?

The importance of early fault detection in electric motors has attracted the attention of research groups, as the detection of incipient faults can prevent damage spreading and increase the lifetime of the motor. At present, studies have focused their attention on optimization procedures used for fault detection in induction machines to achieve a quick and easy-to-interpret assessment at an industrial level. This paper proposes an alternative approach based on the Continuous Wavelet Transform (CWT) for broken bar diagnosis in squirrel cage induction motors. This work uses the Motor Current Signature Analysis (MCSA) method to acquire the current signal of the induction motor. The novelty of this study lies in broken bar detection in electric machines operating at non-load by analyzing variations in the spectrum of the motor’s current signal. This way, the faults are presented as oscillations in the current signal spectrum. Additionally, a quantification of broken bars for the same type of motors operating at full-load is performed in this study. An experimental validation and the comparison with the Fast Fourier Transform (FFT) technique are provided to validate the proposed technique.

Featured Image

Read the Original

This page is a summary of: Broken Bar Diagnosis for Squirrel Cage Induction Motors Using Frequency Analysis Based on MCSA and Continuous Wavelet Transform, Mathematical and Computational Applications, April 2017, MDPI AG,
DOI: 10.3390/mca22020030.
You can read the full text:

Read

Resources

Contributors

The following have contributed to this page