What is it about?

Clinical Performance of Supraglottic Airway Devices in Adults for Short Surgical Procedures

Featured Image

Why is it important?

Aim: In the present study we compared the clinical performance of the I-gel and LMA in terms of the effectiveness and safety administration in anesthetized patients. Materials & Methods: A total of 100 patients with requirement of different abdominal surgery were included in the study. Water soluble jelly was used to lubricate I-gel and LMA-Proseal. An experience anaesthesiologist inserted each of the devices. Both the devices were set by taping the tube over the chin and lubricated gastric tube was situated into the stomach through the gastric channel. Results: The average airway sealing pressure with LMA – ProSeal was 29.6 cm H2O and with I-gel was 25.27 cm H2O, the difference was set up to be statistically significant (p<0.05). There was no occurrence of bronchospasm/laryngospasm, aspiration/regurgitation and hoarseness in both the groups. Conclusion: I-gel is a straight forward tool which is uncomplicated to insert without much of manipulations quickly. It has a possible benefit of effectual seal force which is fewer as compared to LMAProseal, but is sufficient to avoid aspiration and preserve an effective ventilation and oxygenation.

Perspectives

Aim: In the present study we compared the clinical performance of the I-gel and LMA in terms of the effectiveness and safety administration in anesthetized patients. Materials & Methods: A total of 100 patients with requirement of different abdominal surgery were included in the study. Water soluble jelly was used to lubricate I-gel and LMA-Proseal. An experience anaesthesiologist inserted each of the devices. Both the devices were set by taping the tube over the chin and lubricated gastric tube was situated into the stomach through the gastric channel. Results: The average airway sealing pressure with LMA – ProSeal was 29.6 cm H2O and with I-gel was 25.27 cm H2O, the difference was set up to be statistically significant (p<0.05). There was no occurrence of bronchospasm/laryngospasm, aspiration/regurgitation and hoarseness in both the groups. Conclusion: I-gel is a straight forward tool which is uncomplicated to insert without much of manipulations quickly. It has a possible benefit of effectual seal force which is fewer as compared to LMAProseal, but is sufficient to avoid aspiration and preserve an effective ventilation and oxygenation.

Red Flower Publication Publications
Red Flower Publication Pvt Ltd

Read the Original

This page is a summary of: Assessment of Clinical Performance of Supraglottic Airway Devices in Adults for Short Surgical Procedures, Indian Journal of Anaesthesia and Analgesia, January 2018, Red Flower Publication Private, Ltd.,
DOI: 10.21088/ijaa.2349.8471.5718.7.
You can read the full text:

Read

Contributors

The following have contributed to this page