What is it about?

A simple spectrophotometric method was developed to determine riociguat in bulk and tablet formulation. The present method lies on the oxidation of MBTH by Fe+3 ions in acidic medium to form active coupling species and followed by its coupling with riociguat to form the chromophore having lmax 660 nm.

Featured Image

Why is it important?

Validated the proposed method as per the existing guidelines of ICH. Good linearity (r~ 0.999) was observed for calibration curve in the studied concentration range (6.25 – 37.50 μg mL-1).

Perspectives

Reproducibility, accuracy and precision of the method were confirmed from low values of % RSD.

Prof Ratnakaram Venkata Nadh
GITAM University

Read the Original

This page is a summary of: Determination of Riociguat by Oxidative Coupling Using Visible Spectrophotometry, Oriental Journal Of Chemistry, March 2019, Oriental Scientific Publishing Company,
DOI: 10.13005/ojc/35specialissue107.