What is it about?
Immunomethods were suggested for the investigation of adsorption isotherms because of their ease to quantify the non-adsorbed bovine serum albumin without the need of applying separation methods that could modify the balance between the adsorbed and non-adsorbed proteins. The present work revealed that this method should be applied with caution. Artifacts in the determination of free protein can be generated by the presence of surfactants such as polysorbate 80, widely used in the pharmaceutical and biomedical field, that are needed to preserve the stability of nanoparticle dispersions. It was shown that the presence of traces of polysorbate 80 in the dispersion leads to an overestimation of the amount of bovine serum albumin remaining free in the dispersion medium when determined by both radial immunodiffusion and rocket immunoelectrophoresis. However, traces of poloxamer 188 did not result in clear perturbed migrations. These methods are not appropriate to perform adsorption isotherms of proteins on nanoparticle dispersions containing traces of remaining free surfactant.
Featured Image
Read the Original
This page is a summary of: Protein–nanoparticle interactions evaluation by immunomethods: Surfactants can disturb quantitative determinations, European Journal of Pharmaceutics and Biopharmaceutics, August 2015, Elsevier,
DOI: 10.1016/j.ejpb.2015.05.025.