What is it about?

According to European standards, impulse responses are measured outdoors to check the intrinsic acoustic characteristics of installed noise barriers, like sound reflection and airborne sound insulation, to verify their compliance to design specifications or their quality after some years of life. The European method for measuring sound reflection specifies the usage of an electroacoustic sound source and a microphone grid, in order to obtain a set of impulse responses; these are processed by means of improved algorithms to compute the required results. The impulse responses are acquired using MLS (Maximum Length Sequence) or ESS (Exponential Swept-Sine) as test signals. While the acoustical characteristics of a noise barrier obtained using the two signals are generally equivalent, in critical conditions e e.g. excessive background noise or local meteorological variability e some discrepancies may occur. Moreover, different type of background noise (broadband or impulsive) give different effects on the final result, using MLS or ESS test signals. This paper presents a series of experiments designed to put in evidence the differences between Reflection Index measurements performed in the mentioned critical conditions, done using MLS or ESS signals. The relative advantages and drawbacks are analysed and discussed in detail. Conclusions are drawn on the selection of the best test signal for each situation.

Featured Image

Read the Original

This page is a summary of: Sound reflection measurements on noise barriers in critical conditions, Building and Environment, December 2015, Elsevier,
DOI: 10.1016/j.buildenv.2015.06.023.
You can read the full text:

Read

Contributors

The following have contributed to this page